S'abonner

Diode Laser (980 nm) Vaporization in Comparison With Transurethral Resection of the Prostate for Benign Prostatic Hyperplasia: Randomized Clinical Trial With 2-year Follow-up - 27/08/14

Doi : 10.1016/j.urology.2014.05.027 
Mohammad Reza Razzaghi, Mohammad Mohsen Mazloomfard , Hooman Mokhtarpour, Aida Moeini
 Department of Urology, Laser Application in Medical Sciences Research Center, Tajrish Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran 

Reprint requests: Mohammad Mohsen Mazloomfard, M.D., Department of Urology, Laser Application in Medical Sciences Research Center, Tajrish Hospital, Shahid Beheshti University of Medical Sciences, Tehran 1989934148, Iran.

Abstract

Purpose

To compare outcomes of diode laser vaporization of prostate with transurethral resection of the prostate (TURP) as a gold-standard treatment.

Materials and Methods

A total number of 115 patients with benign prostatic hyperplasia underwent TURP and 980-nm diode vaporization of prostate in a balanced randomization (1:1) from 2010 to 2012 and were followed up for 24 months. Baseline characteristics of the patients, perioperative data, and postoperative outcomes were compared. The primary end point of the study was assessing the values of International Prostate Symptom Score (IPSS), and maximum flow rate (Qmax) to predict the functional improvement of each group. The trial is registered at www.irct.ir (number IRCT201202138146N3).

Result

The mean age (± standard deviation) of the patients was 68.2 ± 7.8 years in TURP and 68.5 ± 8.8 in diode groups. In TURP and diode groups, the operation time was 54.9 ± 15.3 vs 60.6 ± 22.6 minutes (P = .14), Foley catheterization time was 88.9 ± 22.5 vs 20.1 ± 4.6 hours (P = .0001) and postoperative hospital stay was 59.9 ± 14.4 vs 25.8 ± 9.2 hours (P = .0001) respectively.

Outcome with regard to increase in Qmax, decrease in IPSS, and decrease in postvoid residual urine volume showed a dramatic improvement in both groups during the first 6 months. In the TURP group, the values of IPSS and Qmax were respectively lower and higher than diode patients at 12 and 24 months of follow-up.

Conclusion

According to our study, diode laser vaporization (980 nm) offers a safe and feasible procedure in the management of patients with symptomatic benign prostatic hypertrophy; however, at longer follow-up the functional outcome of diode laser vaporization has been less efficient than TURP.

Le texte complet de cet article est disponible en PDF.

Plan


 Financial Disclosure: The authors declare that they have no relevant financial interests.
 This study was approved by Laser Application in Medical Sciences Research Center, Shahid Beheshti University of Medical Sciences, as a research project.


© 2014  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 84 - N° 3

P. 526-532 - septembre 2014 Retour au numéro
Article précédent Article précédent
  • Editorial Comment
  • Kevin R. Anderson
| Article suivant Article suivant
  • Determining the Efficacy of Ultrasonography for the Detection of Ureteral Stone
  • Toru Kanno, Masashi Kubota, Hiromasa Sakamoto, Ryuichi Nishiyama, Takashi Okada, Yoshihito Higashi, Hitoshi Yamada

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.